Partial Discharge

voltage discharge within an insulator causing dielectric breakdown.

See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test


Showing results: 106 - 120 of 133 items found.

  • Ultrasonic Leak Detection Camera

    Leakshooter LKS 1000-V.2 - Synergys Technologies

    1st ultrasonic compressed air, gaz and vacuum leak detector with camera. Specialy dedicated to visualize the spots where compressed air is leaking, the LEAKSHOOTER LKS 1000 – V.2 has many other applications such as : steam trap monitoring, bearing monitoring, electrical applications like partial discharge, corona effects, punctured isolators, electrical tracking detection.

  • Solution for Industrial Monitoring

    PDScope - Techimp HQ S.r.L

    Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.

  • Cable Test Termination System

    CTTS Series - Shanghai Jiuzhi Electric Co., Ltd.

    CTT series cable test terminations are used to test Plastic insulated high-voltage cables. The specific advantages of this series versus conventional terminations are fast and convenient assembly. The terminations can be used for partial discharge (PD) measurements, impulse voltage testing, loss factor (tan delta) measurements and, if the cable ends are carefully prepared, for breakdown testing (step test).

  • Insulation Resistance Meter

    AMIC-15k1 - Amperis sl

    *The partial discharge indicator PDI.*Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD*Allows to test the electrical durability of the tested object - indication of breaking voltage.*The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.

  • Electrical Safety Multi-Analyzer

    TOS9300 Series - Kikusui Electronics Corp.

    The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • High Frequency Current Transformer

    HFCT - IPEC Ltd.

    The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.

  • Cable Diagnostic Tools

    High Voltage Inc.

    For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.

  • Compact Ultrasonic Testing Device

    SONAPHONE® Pocket - SONOTEC GmbH

    With the SONAPHONE Pocket you identify problems even before they arise and create value at all levels of your company. Just by detecting and eliminating leaks you can reduce the energy costs for your compressed air system up to 30 percent. This also has positive effects on your operational safety and system productivity through early warning of bearing failure and evidence of partial electrical discharges.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • UHF PD Detector

    Megger Group Ltd.

    Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.

  • Horn Antenna

    Techimp HQ S.r.L

    Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.

  • Gas Insulated Transformer System

    YDSW Series - Shanghai Jiuzhi Electric Co., Ltd.

    SF6 insulated Test Transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and in the field, and for testing the other substation equipment. It is also the portable and easy maintenance solution. The SF6 test transformers can be flanged directly to the GIS for testing which make the partial discharge test easy and quick. These systems are particularly suited for on-site tests of GIS after installation. In the factory, they are used to test sub-assemblies and components directly in the manufacturing line.

  • Test & Automation

    Power Diagnostix Systems GmbH

    Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.

  • Electrical Safety Testers

    Kikusui Electronics Corp.

    a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • Flexible Magnetic Coupler

    FMC - Techimp HQ S.r.L

    The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.